Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Product Groups
High Performance Multi-Function I-O USB Data Acquisition Modules
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
OMB-DAQ-2416
PLACE ORDER 
  • 16 Differential or 32 Single-Ended Analog Inputs, Expandable to 32 Differential/ 64 Single-Ended Channels
  • 24-Bit Resolution
  • Thermocouple or Voltage Input
  • Nine Software-Selectable Voltage Ranges: ±20V, ±10V, ±5V, ±2.5V, ±1.25V, ±0.625V, ±0.312V, ±0.156V, and ±0.078V
  • Analog Inputs Can be Configured for Thermocouples (Up to 16 Differential Inputs)
  • 1000 Samples/Sec Aggregate Throughput
  • Built-In Cold Junction Compensation and Open Thermocouple Detection
  • Eight Lines of High-Drive Digital I/O
  • Two 32-Bit Counters
  • 500V Isolation Between Signal I/Os and the Host Computer
  • OMB-DAQ-2416-4AO Also Includes 4 Analog Outputs
 Manuals (contact with email : [email protected])
 Print
Description

Description

The OMB-DAQ-2416 and the OMB-DAQ-2416-4AO are highlyaccurate, multi-function measurement and control modulesfor the USB bus. These modules are 24-bit analog input devices forvoltage or temperature, with eight digital I/O lines and two counters.In addition to the features listed, the OMB-DAQ-2416-4AO alsoincludes four analog output channels with 16-bit resolution,±10V output range, and an aggregate 1000 Hz update rate.

System Expansion
With the addition of an optional OMB-AI-EXP32 analog inputexpansion module, the number of analog input channels onthe OMB-DAQ-2416 or OMB-DAQ-2416-4AO can bedoubled—increasing from 16 differential/32 single-endedinputs, to 32 differential/64 single-ended inputs. The expansionmodule also provides an additional 16 channels of DIO, bringingthe total DIO count of the mated pair to 24.

All features of the OMB-DAQ-2416 series module are included whenthe OMB-AI-EXP32 is attached, including the ability to accommodatethermocouples on any input channel, built-in cold junctioncompensation, and open thermocouple detection. TheOMB-AI-EXP32 can be plugged directly into a OMB-DAQ-2416series module. The packaging for the OMB-DAQ-2416 series and theOMB-AI-EXP32 ensures ease of use in a variety of applications.Detachable screw terminals facilitate attaching and removingwithout re-wiring. The modules can easily be DIN-rail mounted for rackapplications.

Software
The OMB-DAQ-2416 Series modules ship with an impressivearray of software, including TracerDAQ®, a full-featured, out-of-the-box data logging, viewing, and analysis application. Driver support and detailed example programs are included for Universal Library programming libraries for Microsoft®Visual Studio® programming languages, and other languages,including DASYLab®, and ULx for NI LabVIEW® (comprehensivelibrary of VIs and example programs compatible with 32-bit and 64-bitLabVIEW 2010 or later) and InstaCalTM installation, calibrationand test utility-powerful solutions for programmers and nonprogrammersalike. These modules operate under Microsoft Windows® VISTA/7/8/10(32-bit and 64-bit) operating systems.

The OMB-DAQ-2416 Series data acquisition modules are suppliedwith TracerDAQ software which is a collection of four virtual instrumentapplications used to graphically display and store input data andgenerate output signals:

• Strip Chart—Log and graph values acquire from analoginputs, digital inputs, temperature inputs andcounter inputs
• Oscilloscope—Display values acquired from analog inputs
• Function Generator—Generate waveforms for analog outputs
• Rate Generator—Generate waveforms for counter outputs

TracerDAQ PRO is an enhanced version of TracerDAQ.A comparison of some of the features included in TracerDAQ vsTracerDAQ PRO is shown on the PDF.

SPECIFICATIONS
A/D CONVERTER
(OMB-DAQ-2416, OMB-DAQ-2416-4AO)
A/D Converter Type:
24-bit sigma delta
A/D Data Rates:3750 samples/sec (S/s), 2000 S/s, 1000 S/s, 500 S/s, 100 S/s, 60 S/s, 50 S/s, 25 S/s,10 S/s, 5 S/s, 2.5 S/s
Input Isolation: 500 Vdc min between field wiring and USBinterface
Common Mode Rejection: Thermocouple mode, 110 dB;voltage mode, 90 dB

ANALOG INPUTS
(OMB-DAQ-2416, OMB-DAQ-2416-4AO, OMB-AI-EXP32)
Number of Channels:
16 differential/32 single-ended(thermocouples require differential mode) on OMB-DAQ-2416or OMB-DAQ-2416-4AO. The OMB-AI-EXP32 is a multiplexer-based channel expansion module that adds an additional 16 differential/32 singleended channels.
Maximum Input Voltage: ±30V (power on), ±10V (power off)
Input Impedance: 2 GΩ (power on), 390 Ω (power off)
Input Leakage Current: ±10.6 nA (OMB-DAQ-2416,OMB-DAQ-2416-AO); ±20 nA (OMB-AI-EXP32);±1µA max for input voltage >±30 V
Input Capacitance: 590 pF
Crosstalk: 100 dB adjacent channels
Channel Gain Queue: Up to 64elements, software configurable channel and range
Warm-Up Time: 45 minutes max (OMB-DAQ-2416,OMB-DAQ-2416-4AO); 15 minutes max (OMB-AI-EXP32)
Open Thermocouple Detect: Automatically enable when a channel is configured for athermocouple sensor.
CJC Sensor Accuracy: ±0.15°C typical (15 to 35°C); ±0.5°C max (0 to 55°C)


ANALOG OUTPUT
(OMB-DAQ-2416-4AO ONLY)
Number of Channels:
4
Resolution: 16-bit
Range: ±10 Vdc
Absolute Accuracy: ±16.0 LSB
Relative Accuracy: ±4.0 LSB
Differential Non-Linearity: ±0.25 LSB typical; ±1 LSB max
Current: ±3.5 mA max
Power On and Reset State: DACs cleared to zero scale, 0V ± 50 mV
Noise: 30 µVRMS
Settling Time: 45 µs
Slew Rate: 1.0 V/µs
Throughput: Single channel, 1000 S/s (max, system dependent); multiple channels, 1000 S/s divided by the number of channels (max, system dependent)

ANALOG INPUT/OUTPUT
CALIBRATION
Recommended Warm-Up Time:
45 minutes max
Calibration: Firmware calibration
Calibration Interval: 1 year
Calibration Reference: 10.000V, ±5 mV max; actual measuredvalues stored in EEPROM
Tempco: 5 ppm/°C max
Long Term Stability: 30 ppm/1000 hrs

DIGITAL INPUTS
(OMB-DAQ-2416, OMB-DAQ-2416-4AO,OMB-AI-EXP32)
Number of Digital I/O

Channels: 8 (OMB-DAQ-2416, OMB-DAQ-2416-4AO);16 (OMB-AI-EXP32)
Configuration: Each DIO bit can be independently read from (DIN) or written to (DOUT). The DIN bits can be read at any time whether the DOUT is active or tri-stated.
Voltage Range: 0 to 15 Vdc
Type: CMOS (Schmitt trigger)
Characteristics: 47 kΩ pull-up/pulldownresistor, 28 kΩ series resistor
Maximum Input Voltage Range:0 to 20 Vdc max (power on/off, relative to DGND)
Pull-Up/Pull-Down Configuration:All pins pulled up to 5V via individual 47 kΩ resistors (defaultconfiguration); pull-down capability is available by moving internaljumper
Transfer Rate (Software Paced):500 port reads or single bit reads per second typical
Input High Voltage: 1.3V min, 2.2V max
Input Low Voltage: 1.5V max, 0.6V min
Schmitt Trigger Hysteresis: 0.4V min, 1.2V max

DIGITAL OUTPUTS
(OMB-DAQ-2416, OMB-DAQ-2416-4AO, OMB-AI-EXP32)
Number of Digital I/O Channels:

8 (OMB-DAQ-2416, OMB-DAQ-2416-4AO);16 (OMB-AI-EXP32)
Configuration: Each DIO bit can be independently read from (DIN) or written to (DOUT). The DIN bits can be read at any time whether the DOUT is active or tri-stated.
Characteristics: 47 kΩ pull-up,open drain DMOS transistor
Pull-Up Configuration: All pins pulled up to 5V via individual47 kΩ resistors by default
Transfer Rate (Software Paced):500 port writes or single bit writes per second typical
Output Voltage Range: 0 to 5V (no external pull-up resistor, internal 47 kΩ resistors connected to5V by default); 0 to 15V max
Drain to Source Breakdown Voltage: 50V min
Off-State Leakage Current: 0.1 µA
Sink Current Capability: 150 mAmax continuous per output pin; 150 mA max continuous for alleight channels
DMOS Transistor On-Resistance (Drain to Source): 4 Ω

COUNTERS
(OMB-DAQ-2416, OMB-DAQ-2416-4AO)
Number of Channels:
2
Resolution: 32-bit
Counter Type: Event counter
Input Type: Schmitt trigger, rising edge triggered
Counter Read/Write Rates (Software Paced): 500 reads or writes per second (system dependent)
Input Characteristics: 562 kΩ pull-up resistor to 5V, 10 kΩ series resistor
Input Voltage Range: ±15V max
Maximum Input Voltage Range: ±20V max (power on/off)
Input High Voltage: 1.3V min, 2.2V max
Input Low Voltage: 1.5V max, 0.6V min
Schmitt Trigger Hysteresis: 0.4 min, 1.2V max
Input Bandwith (-3dB): 1 MHz
Input Capacitance: 25 pf
Input Leakage Current: ±120 nA
Input Frequency: 1 MHz max
High Pulse Width: 500 ns min
Low Pulse Width: 500 ns min


GENERAL
OMB-DAQ-2416, OMB-DAQ-2416-4AO
DATA ACQUISITION MODULES
Memory:
EEPROM
Microcontroller: One high-performance 8-bit RISC microcontroller with USB interface (non-isolated); onehigh-performance 16-bit RISC microcontroller for measurements (isolated)
Power: 5V ±5%, 340 mA suppliedby included AC adaptor (OMB-DAQ-2416-ADAP)
User Output Voltage: 5V, 10 mA max available (pin 35)
Isolation: 500 Vdc min measurement system to PC
USB Device Type: USB 2.0 (full-speed)
Device Compatibility: USB 1.1, USB 2.0
USB Cable Length: 5 m (16') max
Dimensions: 245 L x 146 W x 50 mm H(9.6 x 5.7 x 2.0")
Input Connections: Detachable screw terminal blocks (accept16 to 30 AWG wire)
Operating Temperature:0 to 50°C (32 to 122°F), 0 to 90% RH non-condensing
Storage Temperature: -40 to 85°C (-40 to 185°F)
Weight: 463 g (16.3 oz)

OMB-AI-EXP32
EXPANSION MODULE
User Output Voltage:

+5 V, 10 mA max available (pin 19)
Dimensions:245 L x 146 W x 50 mm H (9.6 x 5.7 x 2.0")
Input Connections: Detachable screw terminal blocks (accept 16 to 30 AWG wire)
Operating Temperature:0 to 50°C (32 to 122°F),0 to 90% RH non-condensing
Storage Temperature: -40 to 85°C (-40 to 185°F)
Weight: 400 g (14.1 oz)
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors
trodeks.comtrodeks.com - فقخیثنس.زخئ - صصص.فقخیثنس.زخئ