Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Product Groups
Pure PVDF or PolyproFlow Monitoring Systems
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
FP-5100
PLACE ORDER 
  • For Ultra-Pure Confidence
  • For Safe Acid Transport
  • Easy Installation
 Specs
 Manuals (contact with email : [email protected])
 Print
Description

Description

For maintaining critical product purity or for safe transport ofhighly corrosive acids, you can depend on trodeks's all-PVDFflow monitoring systems. Known for its superior heat-resistanceand thermal stability, PVDF is quickly becoming the preferredpiping material in many ultra-pure water and acid transportapplications. Using no dyes or stabilizers, trodeks offers the only"pure" PVDF flow-monitoring system. Available for installation inpipe sizes ranging from ½ to 8", this system is easy both to installand maintain.

FOR ULTRA-PURE CONFIDENCE
Combine trodeks's PVDF flow monitoring system with yourexisting PVDF pipe including SYGEF, PVDF, and SUPERPROLINE. This all-PVDF system completely eliminates thepossibility of contaminated fluid product, making it perfect formeasuring D.I. water in cosmetic, food, and pharmaceuticalproduction. In addition, processes utilizing D.I. water in thesemiconductor industry can be monitored with total confidence.

FOR SAFE ACID TRANSPORT
When pumping hydrofluoric acid to wafer etching tanks...processingsulfuric acid through water treatment skid for regeneration...ortransporting harsh solvents, trodeks's PVDF flow monitoringsystems provide rugged, corrosion-resistant construction.

EASY INSTALLATION
PVDF Sensor installation Tee fittings allow directcompatibility with SYGEF piping, joined by thefusion using special electro heatingelements. The socket fusion processcombines simple handling with highoperational safety and reliability. Whenused in PVDF or SUPER PROLINEpiping systems, a flange connectionis recommended.

RELIABILITY
trodeks’s PVDF Flow Sensor includes the same designfeatures as our standard FP-5300 Sensor, with a ±0.2 fpsaccuracy and ±0.5 fps repeatability.

Flow Range
Pipe
Size
½" ¾" 1" 1¼" 1½" 2" 2½" 3" 4" 5" 6" 8" 10" 12"
Range
(gpm)
1
to
19
1.7
to
34
2.7
to
54
4.7
to
94
6.4
to
127
10.6
to
210
15
to
300
24
to
461
40
to
794
63
to
1247
91
to
1801
156
to
3119
246
to
4915
349
to
6977

SPECIFICATIONS

Output Signal: 1 V p-p/fps
Output Frequency: 6 Hz/fps nominal
Max. Viscosity: 1 centipoise (water); up to 5 cp above 5 fps velocity
Materials:
    Transducer Housing: PVDF
    O-Rings: FKM
    Shaft: Hastelloy C (PVDF optional)
    Rotor: PVDF
    Tee Fitting: PVDF
Cable: 7.5 m (25') twisted pair, foil shielded with drain wire
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors