Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Thermocouple Probe - Molded Transition Joint Probes with PFA Insulated Lead Wire
(*)TSS Series
PLACE ORDER                                                 -                         Probes Molded in House to ensure Quality and Performance                        
-                         304SS and Inconel® 600 Sheaths                        
-                         1 m (40 in.) PFA-Insulated Lead Wire with Stripped Leads                        
-                         Manufactureed with trodeksCLAD®  Compacted Mineral Insulation Cable for Long-Lasting, Low-Drift Performance                        
-                         Lead and Transition Rated to 260°C (500°F)                        
Description
                                    Description
					                    					For long life, drift-free operation, choose SupertrodeksCLAD® XL mineral insulatedthermocouple cable and our rugged transition joint probes, which areavailable in Type K and Ncalibrations.
    | Calibration ANSI Code
 | Sheath Materials
 | SheathDia. mm (in.)
 | T/CJunction UpperTemp.
 °C (°F)
 | Model Number (Seenotes, below)
 | 
  | K Crtrodeks®-
 Altrodeks®
 
 | 304SS | 1.59(1/16) 3.18 (1/8)
 4.78 (3/16)
 6.35 (1/4)
 | 899 (1650) 899 (1650)
 899 (1650)
 899 (1650)
 | KTSS-116(*)-(**) KTSS-18(*)-(**)
 KTSS-316(*)-(**)
 KTSS-14(*)-(**)
 | 
  | Inconel® 600
 | 1.59 (1/16) 3.18 (1/8)
 4.78(3/16)
 6.35 (1/4)
 | 921 (1690) 1071(1960)
 1149 (2100)
 1149 (2100)
 | KTIN-116(*)-(**) KTIN-18(*)-(**)
 KTIN-316(*)-(**)
 KTIN-14(*)-(**)
 | 
  | Super trodeksCLAD®
 XL
 | 1.59 (1/16) 3.18(1/8)
 4.78 (3/16)
 6.35 (1/4)
 | 1038 (1900) 1149 (2100)
 1204(2200)
 1204 (2200)
 | KTXL-116(*)-(**) KTXL-18(*)-(**)
 KTXL-316(*)-(**)
 KTXL-14(*)-(**)
 | 
  | J Iron-
 Constantan
 | 304SS | 1.59(1/16) 3.18 (1/8)
 4.78 (3/16)
 6.35 (1/4)
 | 441 (825) 521 (970)
 621 (1150)
 721 (1330)
 | JTSS-116(*)-(**) JTSS-18(*)-(**)
 JTSS-316(*)-(**)
 JTSS-14(*)-(**)
 | 
  | T Copper-
 Constantan
 
 | 304SS | 1.59(1/16) 3.18 (1/8)
 4.78 (3/16)
 6.35 (1/4)
 | 260 (500) 316 (600)
 371 (700)
 371 (700)
 | TTSS-116(*)-(**) TTSS-18(*)-(**)
 TTSS-316(*)-(**)
 TTSS-14(*)-(**)
 | 
  
 Notes:*Specify Junction: (G)rounded, (E)xposedoror (U)ngrounded.
**Specify length ininches: 6 for 150 mm (6 in.), 12for 300 mm (12 in.), or 18 for 450 mm (18 in.).
SupertrodeksCLAD® XL probes (highlighted inyellow) are alsoavailable in N calibration; substitute NTfor KT in Model Number. Some Type E devices are also available.See ordering examples below and contact Sales for moe info.                    					                  Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors