Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
4-1-2 Digit (Pt100) RTD Meters- 1-8 DIN
DP3002-M
PLACE ORDER                                                 -                         Platinum 100 RTD Input                         
-                         1 mA Excitation Current                         
-                         2-, 3- or 4-Wire Connection                         
-                         0.1°C or 0.1°F Resolution                         
-                         °C or °F, Jumper-Selectable                         
-                         Platinum Curve Linearization                         
-                         120 dB CMR, 70 dB NMR                         
-                         1 mV/deg Linearized Analog Output                         
-                         Bright, 14.2 mm (0.56") LED Display                         
-                         Display Hold and Test                         
-                         115/230 Vac Power                         
-                         EMI/RFI Filter for AC Power                         
-                         Screw-Terminal Barrier Strip                        
-                         Short 104 mm (4.1") Deep ¹/8 DIN Case
 
 Options
-                         Isolated 9 to 32 Vdc or 26 to 56 Vdc Power                         
-                         NEMA 4 (IP65) Splash-Proof Lens Cover                        
Description
                                    Description
					                    					The DP3002-M is a low-cost 4-1/2 digit(±19,999 count) temperature indicator for use withplatinum 100 RTD’s with alpha of 0.00385. It iscomplete with 1 mA sensor excitation, sensor-breakdetection, and platinum curve linearization. Resolutionis 0.1°. Readout can be in °C or °F, as selected bypush-on jumpers. The electrical connection can be by2-, 3-, or 4-wires. High accuracy is provided by positivecurrent feedback and matched, graded components.
STANDARD FEATURES
Mechanical features include a bright 14 mm (0.56")display, a screw-terminal barrier strip for signal andpower, and a compact 1/8 DIN case that requiresless than 104 mm (4.1") behind the panel. Electricalfeatures include jumper selection of °C or °F, alinearized recorder output of 1 mV per degree, and1 mA current excitation. The current source is tied tothe reference of the A/D converter for true ratiometricoperation and immunity to changes in line voltage.
OPTIONS
Power options include isolated 9 to 32 Vdc and26 to 56 Vdc. A splash-proof lens cover which meetsNEMA 4 (IP65) requirements allows the DP3002 to beused in harsh industrial environments.
SPECIFICATIONS
Analog Input
RTD Type: 100 Ω platinum with alpha of 0.00385
Calibration: IEC 751 (IPTS-68)
Configuration: 2-, 3-or 4-wire connection
Polarity: Bipolar
Zero: Adjustable ±20°C (±36°F)
Zero Tempco: ±0.05 deg/deg
 Sensor-Wire Resistance Tempco
Effect Per Conductor:
2-wire: 20 mdeg/Ω/deg, up to 3.8 Ω
3-wire: 50 µdeg/Ω/deg, up to 100 Ω
4-wire: 5.0 µdeg/Ω/deg, up to 100 Ω
Sensor-Excitation Current: 1 mA
Sensor-Break Indication: Meter displays overrange
Overvoltage Protection: 25 Vp 
Noise Rejection
NMR, SIG HI to SIG LO: 70 dB, 50/60 Hz
CMR, ANA GND to PWR GND: 120 dB, DC to 60 Hz
CMV, ANA GND to PWR GND: 1500 Vp per HV test, 354 Vp per IEC spacing. 
Analog Output (Linearized)
Voltage: 1 mV/deg
Calibration Error: Same as given under accuracy
Current: 1 mA maximum
Source Resistance: 68 Ω
Analog-to-Digital Conversion
Technique: Dual-slope, average value
Signal Integration Period: 100 ms
Read Rate: 2.5/s 
Display
Type: 7-segment, red LED
Height: 14 mm (0.56")
Symbols: -1.8.8.8.8
Decimal Points: Four positions, programmable by jumpers behind lens or at connector
Overrange Indication: Four least-significant digits flash 
Accuracy at 25°C
Span Tempco: ±0.005% R/°C on all models plus ±0.05°C/°C for -RC from -200 to -130°C
Celsius/Fahrenheit: Jumper-selectable
Full-Scale Step Response: 1 s
Warmup to Rated Accuracy: 20 min 
Digital Inputs
Level: TTL or 5V CMOS compatible Power
AC Voltages: 115 or 230 Vac, ±15%
AC Frequency: 49 to 440 Hz
DC Voltages: 9 to 32 Vdc, isolated to 300 Vp; 26 to 56 Vdc, isolated to 300 Vp
Power Consumption: 3.7 W nominal
Output Voltages: 4.7 Vdc and -4.7 Vdc ±5%, 10 mA max 
Environmental
Operating Temperature: 0 to 60°C
Storage Temperature: -40 to 85°C
Relative Humidity: 95% at 40°C (non-condensing) 
Mechanical
Bezel: 96 W x 48 H x 5.1 mm D (3.78 x 1.89 x 0.20")
Depth Behind Bezel: 104 mm (4.09")
Panel Cutout: 92 W x 45 mm H (3.62 x 1.77")
Weight: 15 oz (425 g)
Case Material: 94V-0 UL-rated polycarbonate                     					                  Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors