| OUTPUT RATINGS Horsepower: 90 to 132V, 1/4 to 1 hp
 200 to 240V: 1/2 to 71/2 hp
 380 to 480V: 1 to 10 hp
 425 to 660V: 1 to 10 hp
 Frequency Range: 0.1 to 400 Hz
 Overload Rating: 150% for 60 sec
 Frequency Resolution:
 Digital: 0.1 Hz
 Analog: Max (set frequency/1000) Hz
 Frequency Accuracy:
 Digital: ±0.01% of max frequency
 Analog: ±0.2% of max frequency
 Undervoltage Carryover Limit: 0.3 to 25 sec
 MOTOR PERFORMANCE
 Motor Control: Sensorless vector
 Constant and Variable Torque: Standard
 Speed Regulation: 0.5% of base speed
 INPUT POWER
 Voltage: 50/60 Hz ±3 Hz
 100 to 120V: -10% +10%/1-phase
 200 to 240V: -10% +5%/1-phase
 200 to 240V: -10% +5%/3-phase
 380 to 480V: -10% +10%/3-phase
 500 to 600V: -15% +10%/3-phase
 Displacement Power Factor: Better than 0.95
 Efficiency: Typically greater than 95%
 DESIGN TYPE
 Microprocessor: 32-Bit
 Converter Type: Diode
 Inverter Type: Insulated gate bipolar transistor
 Waveform: Sensorless vector
 ENVIRONMENT
 Operating Temperature: -10 to 50°C (14 to 122ºF), -10 to 40°C (14 to 104ºF); above 71/2 hp)
 Humidity: 20 to 90%, non-condensing
 Max Elevation: 1000 m (3281')
 Codes and Standards: NEMA, IEEE, NEC, design standards, UL Listed, cUL listed, CE marked (requires EMI filter)
 Enclosure: Standard, protected chassis (IP20)
 PROTECTIVE FEATURES
 Ground Fault: Standard
 Overload Protection: Standard
 Overcurrent: Standard
 Overvoltage: Standard
 Undervoltage: Standard
 Overtemperature: Standard
 Overload Limit: Standard
 |  | SET UP ADJUSTMENTS, PERFORMANCE FEATURES, OPERATOR CONTROL AND EXTERNAL INTERFACE KEYPAD Alphanumeric Display: Standard, 1 x 4 character
 Digital Indications: Frequency (Hz), Motor Current (amps), User-Defined RUN/STOP, FORWARD/REVERSE and parameters
 Diagnostics: Last 3 trips with cause
 LED Status Indicators: 8; RUN/STOP, FORWARD/REVERSE, Hz, amps, user defined, and input speed
 Operator Functions: START/STOP, speed control (digital or potentiometer), RESET, SETUP keys and ENTER
 I/O TERMINAL BLOCK
 Analog Inputs: 2 Inputs; 0 to 10 Vdc, 4 to 20 mA
 Potentiometer: 1 to 2K
 Analog Voltage: Nominal 10 Vdc, 10K input impedance
 Analog Current: Nominal 4 to 20 mA 250
 Digital Inputs: 6 programmable inputs
 Digital Outputs: 1 programmable open collector and 1 form C relay contact
 Analog Monitor Output: Analog meter; frequency or output current dynamic brake chopper
 PROGRAMMABLE PARAMETERS
 Out of the Box: Factory settings loaded for quick start-up
 Accel. and Decel.: 2 separately adjustable linear or S curve times; 0.1 to 3000 sec
 Auto Restart: Overcurrent, overvoltage and undervoltage with 4 selectable retry restart modes
 DC Injection Braking:
 External Fault: Terminal input
 Jog: Terminal input
 Fault Reset: STOP/RESET or terminal input
 I/O: NO/NC Selectable
 Jump Frequencies: 3; with adjustable width
 Parameter Security: Programmable software lock
 Preset Speeds: 7 preset speeds
 PID Controller: PID process control
 Reversing: Keypad or terminal
 Speed Setting: Keypad, terminal or pot
 START/STOP Control: Keypad or terminal
 Stop Modes: Decel, coast or DC injection
 RELIABILITY
 Pretested Components: Standard
 Surface Mount Technology: Standard(PCBs) Computerized
 Testing: Standard
 Final Test with Full Load: Standard Eaton's Cutler-Hammer Engineering
 Systems and Service: National network of AF drive specialists
 |