Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
Product Groups
PTFE Liquid Flow Sensors
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
FPR-1500
PLACE ORDER 
  • Provides Highly Linear 0 to 5 Vdc Output Signal and Buffered Linear Pulse Output Signal for Totalizing
  • Micro-Liquid Flow Rates as Low as 15 ml/min Can Be Measured with High Precision
  • Usable with a Variety of Low Viscosity Liquids Including Many Corrosive Liquid Chemicals
 Specs
 Manuals (contact with email : [email protected])
 Print
Description

Description

FPR1501 Series flow sensors canmeasure extremely low flow ratesfrom 15 mL/min. They are suitablefor a wide variety of industrial,commercial, and laboratory flowapplications.

Because the FPR1501 flow sensorshave only PTFE and sapphirewetted surfaces, it is anticipated thatthey will replace conventional glasstube and ball flowmeters in manyapplications in which an electricalsignal proportional to flow rate isdesirable, even in very corrosiveapplications in which the liquid islow in viscosity (i.e., less than10 centistokes).

Models use a Pelton-type turbinewheel to determine the flow rate ofthe liquid. The rotation rate of theturbine wheel is linear over a largedynamic range. The electro-opticalsystem consists of a diode emittingenergy in the infrared spectrum. Lightenergy is interrupted and passedfrom 8 small holes in the small turbinewheel. This reflected light energy isdetected by a photodiode. Thus, as the turbinewheel rotates inresponse to the liquidflow rate, electricalpulses are generated.Processing circuitryprovides a DC voltageoutput and bufferedsquare-wave outputpulses that areproportional tothe flow rate.

Tube Fitting:
1/8" tube fittings for flowrates up to 100 ml/min
¼" tube fitting for flow rates from 100 ml/min. to 2 liters/min
3/8" tube fitting for flow rates greater than 2 liters/min.

SPECIFICATIONS
Output Signal: 0 to 5 Vdc, adjustable ±20% (typical) and pulse output from 0 to 300/500 pps (typical) @ 7.5 Vdc peak pulse height-linear
Power Requirements: 12 to 15 Vdc regulated, 50 mA
Standard Sensor Material: PTFE, sapphire, Perfluoroelastomer gasket; PFA compression tube fittings
Pressure Rating: 4 bar (60 psig) max
Temperature Rating: 0 to 70°C (32 to 158°F)
Temperature Sensitivity: ±0.2%/°C
Accuracy: ±3% FS
Repeatability: ±0.2% FS from 20 to 100% of rated max flow
Dimensions: 55.6 x 48.0 x 58.9 mm (2.19 x 1.89 x 2.32") not including fittings
Applicable Liquids: Many low-viscosity (<10 centistokes) liquids; check compatibility with wetted materials; specify liquid when ordering
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors