Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
DIN Rail Mount Transmitters with RFID Communications
TXDIN400
PLACE ORDER                                                 -                         TXDIN401 Temperature Transmitter Accepts Pt100 or Ni100 RTD Inputs and Types J/K/T/E/R/S/B/N Thermocouples                        
-                         TXDIN402 Accepts Process Voltage, Current or Resistance Input                        
-                         User Configurable via TX400-RFID (NFC) Programmer and Configuration Software                        
-                         High Accuracy                        
-                         16-Bit Conversion                        
-                         Isolated                        
-                         Linearized                        
-                         Transmitters Have 2624 Word Non-Volatile Memory (Circular Buffer) for Data-Logging with User-Selectable Sampling Time                        
-                         FREE Downloadable RF Programmer Configuration Software from trodeks                        
Description
                                    Description
					                    					The TXDIN401 and TXDIN402 DIN rail mounttransmitters transform a temperature or process signalinto a linearized 2-wire loop-powered 4 to 20 mA output.Model TXDIN401 is a temperature transmitter thataccepts Pt100 or Ni100 RTD and Types J/K/T/E/R/S/B/Nthermocouples. Model TXDIN402 is a process inputtransmitter that accepts voltage, current or resistanceinput. The characteristics of these converters ensurehigh precision on the reading scale with 16-bitconversion. The 4 to 20 mA output can be scaled basedon the desired input range.
The programming procedure uses an RFID (NFC)mode with the dedicated TX400-RFID programmer thatallows the user to make all calibrations and settingsquickly and without the need to power and connectup the transmitter. Simply connect the TX400-RFIDprogrammer to the USB port of your PC, start the RFProgrammer configuration software and place thetransmitter on top of the TX400-RFID programmerto establish communications. These transmitters arealso provided with a data logging function for theinput signal. Transmitters have a non-volatile memory(circular buffer) for data-logging with user-selectablesampling time. The user selects the sampling time(1 to 3600 seconds) and then each time the 4 to20 mA loop powers the device, the input value isstored to non-volatile memory.
Using the TX400-RFID programmer along with theRF Programmer configuration software (software isa free download from trodeks) the user can:
    • Completely configure the transmitter includingscaling the 4 to 20 mA output to desired input range
    • Implement field calibration to compensate for gainand offset errors
    • Download logged data to PC for visualization and printing
Specifications
RTD Input Types and Ranges (TXDIN401 Only)
    Pt100 (a = 0.00385): 2, 3, or 4-wire connection,-200 to 600°C (-328 to 1112°F)
    Ni100 (a = 0.00618): 2, 3, or 4-wire connection,-60 to 180°C (-76 to 356°F)
Thermocouple Input Types (TXDIN401 Only): J/K/T/E/R/S/B/N/mV
Process Input Types and Ranges (TXDIN402 Only):
    Voltage: 0 to 10 V
    Current: 0 to 20 mA (4 to 20 mA default)
    Resistance: 0 to 4000 Ω
Output Resolution: 2 µA
Over-Range Output: fs + 5°C
Under-Range Output: fs - 5°C
Output Error (Failure): Selectable between 21 mA or 3.8 mA
Current Output Protection: 30 mA approx
Rejection: 50 to 60 Hz
Maximum Transmission Error: 0.1% FS or 0.2°C whicheveris greater
Sampling Time: 300 msec
Response Time (10 to 90%): 600 msec
Non-Volatile Memory (Circular Buffer) for Data Logging: 2624 word
Cable Resistance: 20 Ω max
Temperature Coefficient: < 100 ppm
Power: 2-wire loop powered; operating range 6 to 32 Vdc
Isolation: Galvanic, 1 KVac input/output
Operating Environment: -40 to 85°C (-40 to 185°F),30 to 90% RH (non condensing)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Mounting: 3 mm DIN rail
Material: Enclosure, polycarbonate; front panel, silicone
Enclosure Rating: NEMA 1 (IP20) according to CE, EN 61000-6-4, EN 61000-6-2
Programming: Wireless with RFID technology (NFC)
Software: Windows® XP/7/8 (32-bit and 64-bit), Windows 10 (64-bit)
Connection: Screw terminals
Weight: 30 g (1.05 oz) approx
Dimensions: 90 H x 18 W x 64 mm D (3.54 x 0.71 x 2.52")                    					                  Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors
trodeks.comtrodeks.com - فقخیثنس.زخئ - صصص.فقخیثنس.زخئ