Your Source for Process Measurement & Control
UK
44-796-072-6366
Germany
49-178-631-1266
3-A Approved Sanitary RTD Sensor with M12 Connector for use in Sanitary or Hygienic Clean-In-Place (CIP) Applications
PRS-M12 Series
PLACE ORDER                                                 -                         Pt100 Class A Sensor with M12, 4-Pin Connection Allows for Quick and Easy Installation.  An M12 Extension Cable is Required for Installation.                        
-                         3-A Approved Design, Flanges conform to ASME-BPE-2007                        
-                         Can Be Used In Sanitary, Hygienic, and Clean-In-Place Food, Dairy, Beverage  and BioPharmaceutical Applications                        
-                         Wetted Surfaces are 316L Stainless Steel With a Surface Finish = 32 Microinches or Better                        
-                         Standard Duty and Heavy Duty Constructions Available                        
-                         Process Measurement Temperature Range: -50 to 200°C (-58 to 392°F)                        
Description
                                    Description
					                    					Note: These Sensors Require an M12 Extension Cable to Connect the Sensor To Your Instrumentation.  A Partial List Of Our M12 Extension Cables is Included in the Ordering Table Below.
Sanitary Temperature Sensor Specifications Include:
3A Approved 316L stainless steel wetted surfaces with surface finishes of 32 microinches or better.
Mounting flanges are 16AMP style conforming to ASME-BPE-2007 for proper fit with CIP systems. Probe designs include a 1/4" diameter standard duty and a stepped 3/16 to 3/8" heavy duty design. Standard probe lengths of 3, 4, 5 or 6" available from stock, other lengths available as special orders.
 Sensor is a 4-wire, 100 ohm, Class A, Platinum Pt100 RTD meeting the requirements of IEC 60751.
Connection is a 4-pin M12 plug style connector.
These sensors can be used with 2-wire, 3-wire or 4-wire systems see information below.
Insulation resistance: 100 megohms minimum at 100 VDC.
Thermal response time of less than 2.5 seconds in water flowing at 3 ft/sec (63% response).
 The 3-A Approved trodeks® PRS-S-M12 and PRS-H-M12 SeriesRTD Sensors are designed for use in Sanitary or Hygienic Clean-in-Place applications in the Food, Dairy, Beverage and BioPharmaceutical industries.  These temperature sensors are manufactured with 316L stainless steel housings that meet the dimensional and finish requirements of 3-A Standard 74-05 and ASME BPE-2007, and are welded and processed to provide a clean, smooth, 32 microinch or better surface finish in the wetted areas for Clean-in-Place processes.
The 3-A Approved trodeks® PRS-S-M12 and PRS-H-M12 SeriesRTD Sensors are designed for use in Sanitary or Hygienic Clean-in-Place applications in the Food, Dairy, Beverage and BioPharmaceutical industries.  These temperature sensors are manufactured with 316L stainless steel housings that meet the dimensional and finish requirements of 3-A Standard 74-05 and ASME BPE-2007, and are welded and processed to provide a clean, smooth, 32 microinch or better surface finish in the wetted areas for Clean-in-Place processes.
The probe stems are manufactured in two configurations; with a standard ¼" diameter probe for standard duty service, and a stepped 3/8" to 3/16" diameter probe design for good response times in heavy duty applications.
In addition to the standard 1½-16AMP process connection, these can be provided in the following sizes and styles: 
	| Process Connection | Model Number Code | 
|---|
	| 3/4"-16AMP | -B1- | 
	| 1" and 1½"-16AMP | -D1- | 
	| 2"-16AMP | -E1- | 
	| 2½"-16AMP | -F1- | 
	| 3"-16AMP | -G1- | 
	| 4"-16AMP | -H1- | 
If you need a process connection that is not listed above, please contact our sales department for availability.
A 4-Pin M12 Connector provides a quick and convenient connection point for process wiring.  trodeks offers a full line of M12 extension and patch cables in a variety of cable materials, lengths and connector configurations.
These sanitary RTD sensors are supplied standard as 4-wire assemblies with 4-pin connectors.
When used in 3-wire applications, use pins A, B and C as shown in the wiring detail below.
  When used in 2-wire systems, connect one wire to pins A or B and the second wire to pins C or D as shown below.
  
			| Wiring Diagram | 
			|  | 
This M12 connector style sensor is also available with a Thermistor sensing element in order to accommodate a wide variety of input requirements. 
                    					                  Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors