3-A Approved Sanitary RTD Sensors with Polypropylene or Stainless Steel Connection Heads
PRS-NB9W Sanitary RTD Sensors
PLACE ORDER                                                 -                         3-A Approved Design, Along with ASME-BPE-2007 Flange Geometry, Insures Trouble-Free Cleanability and Interchangeability                        
-                         Can Be Used in Sanitary, Hygienic and Clean-In-Place Food, Dairy, Beverage and BioPharmaceutical Processes                        
-                         Wetted Surfaces are 316L Stainless Steel, Surface Finish = 32 Microinch or Better                        
-                         Standard Duty ¼" (0.250") Diameter or
 Heavy Duty Stepped 3⁄8" to 3⁄16" Diameter Probes Available
-                         4-Wire, Pt100, Class A Platinum RTD Sensor (100.00 ±0.06 &trodeks; at 0°C) Standard                        
-                         Process Measurement Temperature Range: -50 to 200°C (-58 to 392°F)                        
-                         Compatible with 3-Wire and 2-Wire RTD Instruments & Transmitters                        
Description
                                    Description
					                    					Sanitary Sensor Specifications Include:
316L stainless steel process wetted surfaces with surface finishes of 32 microinches or better.
Probe lengths of 3, 4, 5 or 6 inches available from stock, other lengths available as special orders.
 Sensor Output is a 4-wire, 100 ohm, Class A, Platinum RTD meeting the requirements of IEC 60751.
These sensors can also be used with 2-wire or 3-wire systems see information below.
Insulation resistance:  100 megohms minimum at 100 VDC.
Thermal response time of less than 2.5 seconds in water flowing at 3 ft/sec (63% response).
Optional stainless steel connection heads available.
  The 3-A Approved trodeks® PRS-S-NB9W and PRS-H-NB9W SeriesRTD Sensors are designed for use in Sanitary or Hygienic Clean-in-Place applications in the Food, Dairy, Beverage and BioPharmaceutical industries.  These sensors are manufactured with 316L stainless steel housings that meet the dimensional and finish requirements of 3-A Standard 74-05 and ASME BPE-2007, and are welded and processed to provide a clean, smooth, 32 microinch or better surface finish in the wetted areas for Clean-in-Place processes.
The 3-A Approved trodeks® PRS-S-NB9W and PRS-H-NB9W SeriesRTD Sensors are designed for use in Sanitary or Hygienic Clean-in-Place applications in the Food, Dairy, Beverage and BioPharmaceutical industries.  These sensors are manufactured with 316L stainless steel housings that meet the dimensional and finish requirements of 3-A Standard 74-05 and ASME BPE-2007, and are welded and processed to provide a clean, smooth, 32 microinch or better surface finish in the wetted areas for Clean-in-Place processes.
The probe stems are manufactured in two configurations; with a standard ¼" diameter probe for standard duty service, and a stepped 3/8" to 3/16" diameter probe design for good response times in heavy duty applications. A white polypropylene connection head provides a convenient 3/4" NPT threaded connection point for process wiring.
Food process hygienic temperature sensors can be used to aid food safety inspection compliance and verification of time temperature control. Combined with a  chart recorder  model CTXL you can temperature monitor a CCP ( Critical Control Point) or sanitation time and move toward a HACCP (Hazard Analysis Critical Control Point) compliance plan.
In addition to the standard 1½-16AMP process connection, these can be provided in the following sizes and styles: 
	| Process Connection | Model Number Code | 
|---|
	| 3/4"-16AMP | -B1- | 
	| 1" and 1½"-16AMP | -D1- | 
	| 2"-16AMP | -E1- | 
	| 2½"-16AMP | -F1- | 
	| 3"-16AMP | -G1- | 
	| 4"-16AMP | -H1- | 
If you need a process connection that is not listed above, please contact our sales department for availability.
These sensors are supplied standard as 4-wire assemblies with two red wires and two white wires.  When used in 3-wire applications simply connect to three of the wires (typically two red and one white). When used in 2-wire applications, connect to one of the red wires and one of the white wires.
  
 These sensors are also available with  and  sensors to accommodate any process input requirement.
                     					                  Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors
trodeks.comtrodeks.com - فقخیثنس.زخئ - صصص.فقخیثنس.زخئ