Air Velocity Meter with CFM-BTU-Dew Point-Wet Bulb-Temp-Humidity
TRODEKS Engineering | Thermocouples, Pressure Transducers, Flow Meters, PID Controllers
HHF11A
PLACE ORDER 
  • Measures: Temperature, Dew Point, Relative Humidity, Wet Bulb, Air Velocity, Air Volume, Capacity
  • Lightweight, Easy to Maneuver Measurement Vane
  • Single Point Average
  • °C/°F Selectable
  • Auto Power Off After 10 Minutes of Inactivity
  • Jumbo Display
  • Ball Bearing Fan
 Specs
 Manuals (contact with email : [email protected])
 Print
Description

Description

The HHF11A anemometer can measure air flow, humidity, dewpoint, wet bulb, air volume, andcapacity. The built-in microprocessorensures high accuracy. It can alsotrack the maximum and minimumvalues along with current readings,displaying the flow rate in the user’schoice of meters per second orcubic feet per minute.

With its low-friction, ball-bearing,mounted-wheel design, the HHF11Ais accurate at both high and low airvelocity. The impeller is accurate to5% FS and can measure the slightestbreeze (0.3 m/s). Other featuresinclude single-point averaging of airvolume and capacity, °C/°Fselection, and auto shut-off after10 minutes of non-use.

SPECIFICATIONS
Maximum Reading: 99,999
Cable Length: 50 cm extends to 1.5 m (20" extends to approx. 5')
Vane Diameter: 74 mm (2.9")
Vane Size (H x W x D): 164 x 74 x 40 mm (6.45 x 2.9 x 1.57")
Unit Size (H x W x D): 157 x 62 x 28 mm (6.18 x 2.44 x 1.1")
Display Size (H x W): 34 x 47 mm (1.3 x 1.85")
Digit Height: 18 mm (0.7")
Display: High-contrast 5-digit display
Power: 4 “AAA” batteries (included)
Weight: 263 g (9.28 oz) without batteries
Response Time: 1 second
Operating Current: 5 to 8 mA
Operating Temperature: 0 to 50°C (32 to 122°F)
Operating Humidity: Less then 90% RH

Measurement Range Resolution Accuracy
Air Velocity 0.3 to 35 m/s
(1 to 114 ft/s)
0.1 ±5% FS
Air Volume 0 to 99,999 m³/min
(0 to 99,999 ft³/min)
0.1 ±5% FS
Capacity 0 to 99,999 BTU/h
(0 to 99,999 kW)
0.1 ±3% FS
Temperature -20 to 60 °C
(-4 to 140°F)
0.1° ±0.6°C (1°F)
Humidity 0 to 100% 0.1% ±3% FS from 10 to 90%
±5% FS above 90%
Dew Point -68 to 70°C
(-90 to 158°F)
0.1° ±3% FS from 10 to 90%
±5% FS above 90%
Wet Bulb -22 to 70°C
(-7.6 to 158°F)
0.1° ±3% FS from 10 to 90%
±5% FS above 90%
Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors