Description

HHM33 Basic Unit
31/2 digit, 1999 Counts Digital Display
DC Volts: 0 to 2 V/20 V/600 V ±1.2%
AC Volts: 0-200 V/600 V/50 to 500 Hz ± 2.5%
DC Current: 0 to 200 µA/2 mA/20 mA/200 mA/10 A ±2.5%
Resistance: 0 to 200 /2 K/20 K/200 K/20 M ±2.0%
Resolution: 1 mV, 100 mV, 0.1 µA, 0.1
Battery Test: 1.5 V/9 V ±3.5%
Diode Test, 10A Fused, Safety Input Jacks, Safety Test Leads
Overload Protection on All Ranges


HHM34 Basic Unit
31/2 digit, 1999 Counts Digital Display
DC Volts: 0 to 200 mV/2 V/20 V/600 V ±1.2%
AC Volts: 0 to 200 mV/2 V/200 V/600 V/50-500 Hz ±2.0%
DC Current: 0 to 200 µA/20 mA/200 mA/10 A ±1.5%
AC Current:0 to 200 µA/20 mA/200 mA/10 A/50-500 Hz ±2.0%
Resistance: 0-200 /2 K/200 K/20 M±1.5%
Resolution: 100 µV, 0.1 µA, 0.1
Diode Test, Continuity Test, Non-Contact Voltage Indicator
Low-tension lines from 70 to 440Vac 50 to 60 Hz
Data Hold, MAX Hold,10A Fused
Safety Input Jacks, Safety Test Leads
Overload Protection on All Ranges


HHM35 Basic Unit
3200 Counts with Annunciators
Auto Power Off Function
Auto or Manual Range Selection

Bar Graph Display: 12 time/sec. sampling
DC Volts(Auto): 0 to 320 mV/3.2 V/32 V/320 V/600 V ±1.2%
AC Volts(Auto): 0 to 3.2 V/32 V/320 V/600 V/ 50-200 Hz ±2.0%
DC Current: 0 to 320 µA/3200 µA/32 mA/320 mA/10 A ±2.0%
AC Current: 0 to 320 µA/3200 µA/32 mA/320 mA/10 A ±2.5%
Resistance: 0 to 320 /3.2 K/320 K/3.2 M/30 M ±1.5%
Resolution: 100 µV, 0.1 µA, 0.1
Diode Test, Continuity Test, Data Hold, 10A Fused,
Safety Input Jacks, Safety Test Leads,
Overload Protection on All Ranges


Anemometer  |   Automation  |   Accelerometers  |   Calibrator  |   Cartridge Heaters  |   Chart Recorders  |   Cryogenics  |   Custom Pressure Transducers  |   Data Loggers  |   Data Acquisition  |   Dial Thermometers  |   Fiber Optics  |   Fiber Optic Temperature Measurement  |   Flexible Heaters  |   Flow Meters  |   Glass Bulb Thermometers  |   Grippers  |   Heaters  |   Humidity Measurement  |   Integrated Circuit Sensors  |   Immersion Heaters  |   Infrared Thermometers  |   Level Measurement  |   Load Cells  |   M12 Temperature Connectors  |   Magnetic Flow Meter  |   Panel Meter  |   PID Controllers  |   pH meter  |   Pressure Gauges  |   Pressure Transducers  |   Pressure Transmitters  |   Rotameters  |   RTD  |   Remote Process Monitoring  |   Sanitary Sensors  |   Signal Conditioners  |   Stepper Motors  |   Strain Gages   |   Strip Heaters  |   Temperature Controllers  |   Temperature Labels  |   Temperature Measurement  |   Temperature Sensor Manufacturing  |   Temperature Sensors  |   Temperature Transmitters  |   Thermal Imagers  |   Thermistors  |   Thermocouple  |   Thermocouple Wire | Thermowell  |   Ultrasonic Flow Meters  |   Vortex Flow Meter  |   Wireless Sensors